![solidworks 2005 dos solidworks 2005 dos](https://cdn.slidesharecdn.com/ss_thumbnails/0d6a1311-2c3f-4048-9d87-3f5a7e6e83c2-150625235639-lva1-app6891-thumbnail-4.jpg)
SOLIDWORKS 2005 DOS FULL
Before main drawing can be open, system performs download of all used components.Ĭomponents rented in full mode may be edited „in place“ in SolidWorks. Example is a new revision of detail drawing used on assembly. Color green, mean so there is some additional remark for user. Such drawing can not be rented in full mode. Color red means so drawing is blocked by other user or his status. Additionally, some drawings may be highlighted with different colors. Like a default, all checkboxes are on or off, it depends of global system settings. User may choose to download a drawing in full mode or just take a read-only copy.
![solidworks 2005 dos solidworks 2005 dos](https://image.slidesharecdn.com/solidworks-2015-overview-160218192907/95/solidworks-2015-overview-10-638.jpg)
If there are some important info, they is marked in Comments. there is information about user which actually rents drawing (this mean: blocking). Except drawing number, revision, name etc. If they are, system displays additional panel with a list of all additional files which need to be downloaded locally before main drawing can be open. Working with Assemblies During opening every assembly, system checks if there are some referenced drawings (in Autocad syntax called Xrefs). PDM9000 v8.7 – SolidWorks interface description 7Ĥ. To perform complete set of variants, dedicated function in Tools menu is available. Because of speed, only actual variant/configuration is processed. Place during placing part on assembly, PDM sets actually selected variant (if not selected, SW uses last active Configuration saved in Part) Save: during structure analyse, PDM scans physical properties and store it in Variant table. Custom properties set variables with “VARIANT.” prefix will be created for specific Configuration only. Open during opening, configuration is set to actually selected variant. PDM supports Configurations in following operations: Master Variant ($) always corresponds to Default configuration.
SOLIDWORKS 2005 DOS CODE
Variant code must correspond to Configuration Name in SolidWorks. PDM supports this feature on Variants level. Part’s Configurations SolidWorks uses Configurations. PDM9000 v8.7 – SolidWorks interface description 6ģ. PDM9000 v8.7 – SolidWorks interface description 5 This information is stored in variants table. During saving Part or Assembly, PDM asks for Configuration, material and physical mass of model. During opening, part object becomes his number and description which is later used in Assemblies and Drafts. Because of file properties, every part registered in PDM should be open and save by PDM minimum once. Working with Parts Parts are most simply models in SolidWorks. PDM9000 v8.7 – SolidWorks interface description 4Ģ. Drawing rented in Read-Only mode is stored on local drive with RO file attribute so after opening in SolidWorks, this attribute is labeled on caption line. Read-Only mode do not belongs to Open operation but to RENT operation. This will discover or prevent any geometry conflict situation which may occurs in SolidWorks. It is recommended to perform “Save” operation in SolidWorks first. Check In operation, transfers local drawing to the server. Closing drawing performs drawing structure analyze and save a local copy of the file. When drawing is ready and need to be saved, user should switch to PDM and use function “Close + Check in”. Custom properties are later used for composing Partslist definition template. Standard properties are fixed, custom properties are configurable in PDM configuration tables. PDM9000 v8.7 – SolidWorks interface description 3 PDM9000 v8.7 – SolidWorks interface description 2Īfter opening, PDM sets drawing’s properties, which are filled with info from database. After successful download, drawing is loaded into SolidWorks environment. If all is ok, drawing is downloaded from central server into local station. This function first checks user rights for actual drawing. To open a drawing, user should use a function “Check out + Open”. Opening is realized by standard PDM functions like for any other drawings. System will preset these values when user sets proper file format. Parts and Assemblies should be registered like 3D Models and without paper format. Standard operations SolidWorks drawings are registered in PDM with different file format codes: PDM9000 v8.7 – SolidWorks interface description 1ġ. Because this guide is an extension to standard PDM9000 User Guide, some trivial subjects are covered very shortly. This guide covers basic installation implementations at customer side may vary. Interface requires minimum SolidWorks 2004.
![solidworks 2005 dos solidworks 2005 dos](https://michaellorddotme.files.wordpress.com/2018/02/p2080436.jpg)
This description covers PDM9000v8.7 extension regarding cooperation with SolidWorks. PDM9000 v8.7 – SolidWorks Interface User guide